P7-10
Product ID
- -
P7-11
Software version number
Number of decimal places
for load speed display
Default:21
- -
P7-12
0: 0 decimal place
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
If the load speed display coefficient P7-06 is 2.000, the load speed
decimal point P7-12 is 2 (2 decimal places), when the inverter running
frequency is 40.00Hz, the load speed is: 40.00*2.000 = 80.00 (2 decimal
places) display.
Used to set the number of decimal places for the load speed display. The
following example illustrates how the load speed is calculated:
If the inverter is in the stop state, the load speed is displayed as the speed
corresponding to the set frequency, which is “set the load speed”. Taking the
set frequency 50.00Hz as an example, the load speed in the stop state is:
50.00*2.000 = 100.00 (2 decimal places are displayed)
P7-13
Accumulative power-on time
0h〜65535h
-
The cumulative power-on time of the inverter from the factory is displayed.
When this time reaches the set power-on time (P8-17), the output terminal
(24) outputs an ON signal.
P7-14
Accumulative power consumption
0kW〜65535
-
Displays the cumulative power consumption of the inverter
P8: Accessibility
P8-00
JOG running
frequency
0.00Hz〜Maximum
frequency
Default:2.00Hz
JOG acceleration time
0.0s〜6500.0s
Default:20.0s
JOG deceleration time
0.0s〜6500.0s
Default:20.0s
P8-01
P8-02
Define the given frequency and acceleration/deceleration time of the
inverter when jogging. When jog running, the start mode is fixed to the direct
start mode (P 6-0 0 = 0), and the stop mode is fixed to the deceleration stop
(P6-10 = 0).
Acceleration time 1
0.0s〜6500.0s
depend
Deceleration time 1
0.0s〜6500.0s
depend
Acceleration time 2
0.0s〜6500.0s
depend
Deceleration time 2
0.0s〜6500.0s
depend
Acceleration time 3
0.0s〜6500.0s
depend
Deceleration time 3
0.0s〜6500.0s
depend
P8-03
P8-04
P8-05
P8-06
P8-07
P8-08
The definitions of the four groups of acceleration and deceleration are
exactly the same. Please refer to the descriptions of P0-17 and P0-18.
Through the different combinations of multi-function input terminals, you can
switch between 4 groups of acceleration/deceleration time, see P4-01~P4-
05.
The inverter provides 4 sets of acceleration and deceleration time, which
are P0-17\P0-18 and the above three groups of acceleration and
deceleration time.
Jump frequency 1
0.00Hz〜Maximum frequency
Default:0.00Hz
Jump frequency 2
0.00Hz〜Maximum frequency
Default:0.00Hz
Frequency jump
amplitude
0.00Hz〜Maximum frequency
Default:0.00Hz
P8-09
P8-10
P8-11
When the set frequency is within the skip frequency range, the actual
operating frequency will run at a skip frequency that is closer to the set
frequency. By setting the skip frequency, the inverter can be avoided from the
mechanical resonance point of the load.
Two skip frequency points can be set. If both skip frequencies are set to 0,
the skip frequency function is cancelled. The principle of the hopping
frequency and the hopping frequency amplitude is shown in Figure 6-16.
P7-09
Accumulative running time
0h〜65535h
-
Displays the cumulative running time of the drive. When the running time
reaches the setting P8-17, the terminal (12) outputs an ON signal.