4
The maximum opening angle depends on the distance (D) between the gate hinge to the edge of the
pillar. The table below gives the opening angle according to (D)
Pillar
B
1
2
3
4
5
D
Actuator:
Installation Guide
Distance D (mm)
0 < D < 170
0 < D < 110
Angle (º)
90
100
0 < D < 60
D < 20
110
120
Distance D
(mm)
170
160
150
140
130
120
110
100
90
80
Angle max.
(º)
90
100
95
70
60
50
40
30
20
10
0
Distance B
(mm)
110
115
120
135
130
145
140
135
150
100
145
155
150
160
150
160
150
150
105
110
115
120
5
5
5
5
5
5
5
5
5
5
4 or 5
5
4
4 or 5
4
4
4
4
The bracket holes
(Gate side bracket)
INCORRECT
Pillar
hinge pin
> 170mm
CORRECT
Pillar
hinge pin
= 170mm
100mm
IMPORTANT:
If the hinge of your gate is more than 170mm from the edge of the pillar, it is necessary to adapt the
pillar to ensure the hinge is less than 170mm from the edge of the pillar, to reach a 90º opening.
Angle
Pillar
D