ENGLISH
Pag. 23
Or, when equipped with dust adapter:
2.1 Marking
The detectors are equipped with an instrument label with one of the following markings
indicating the explosion protection mode:
Table 3) The data present on the marking label is explained below
Sensitron S.r.l. Viale della Re-
pubblica 48, 20007 Cornaredo
MI Italia
Name and address of the manufacturer of the electrical
device
Conformity marking for the applicable European directi-
ves
AT-EN/.../.../... Identication
s/n
Year
Serial number and year of production
Conformity marking to the ATEX Directive 2014/34/EU
II Electrical equipment for surface plants
2 Category of the electrical devices for use in areas classi-
ed as zone 2
G Electrical equipment for atmospheres with the presence
of ammable gas
GD Electrical equipment for atmospheres with the presence
of ammable gas and combustible dust
Ex db Explosion proof protection mode based on EN 60079-1
Ex ec Protection mode based on EN 60079-7
Ex nC Protection mode based on EN 60079-15
IIC Gas group, acetylene and hydrogen.
T* Temperature class T* for ammable gas.
Ex tc Type of protection for combustible dust by means of
dust-proof enclosure based on EN 60079-31
II 3G Ex db ec nC IIC T* Gc
II 3G Ex db ec nC IIC T* Gc
Ex tc IIIC T5 T***°C Dc
IP65
2. Certications
SMART 3G series gas detectors meet the essential health
and safety requirements in accordance with the ATEX Di-
rective 2014/34/EU.
The gas detectors of the ST series have been designed for
use in potentially explosive atmospheres due to the pre-
sence of gas, vapour, mist and dust, classied as zone 1 or
zone 2 (or zone 21 or 22 when the dust cover is applied)
according to EN 60079-10-1 and EN 60079-10-2 classi-
cation.