SESAMO SMARTPRO
17
Auxiliary output
AUX-OUT
0 = Interlock
1 = Stop open condition
2 = Stop closed condition
3 = Failure
4 = Repetition of lock command
5 = door in movement
0
18
Safety sensors
cofiguration
0 = Monitoring disabled
1 = Monitoring active for closing sensors
2 = Monitoring active for opening sensors
3 = Monitoring active both opening both closing sensors
0
19
Not Used
-
-
20
Opening safety
sensor exclusion
Opening safety sensor angle exclusion.
RANGE: 0 ÷ 40% of total angle opening
0
21
Phase displacement
in opening for
double door
RANGE: 0 ÷ 100
displacement in opening unit of 100 ms (0=syncronized)
0
22
Phase displacement
in closing for
double door
RANGE: 0 ÷ 100
displacement in closing unit of 100 ms (0=syncronized)
0
23
Polarity input
SAFE OPEN
0 = NA (Normally Open)
1 = NC (Normally Close)
1
24
Polarity input
SAFE CLOSE
0 = NA (Normally Open)
1 = NC (Normally Close)
1
25
Polarity input
KEY
0 = NA (Normally Open)
1 = NC (Normally Close)
1
26
Polarity input
START 1
0 = NA (Normally Open)
1 = NC (Normally Close)
0
27
Polarity input
START 2
0 = NA (Normally Open)
1 = NC (Normally Close)
0
28
Polarity input
AUX IN1
0 = NA (Normally Open)
1 = NC (Normally Close)
0
29
Polarity input
AUX IN2
0 = NA (Normally Open)
1 = NC (Normally Close)
0