48
SESAMO SMARTPRO
21. START UP
Verify contacts 8-9, 12-13, 15-16 are closed.
Be sure to have set the parameters of the electric-lock.
DANGER: during LP procedure the safety sensors are not connected.
Be sure no persons are passing through the door. Movement of the doors might
create serious damage to property or people at risk of life-threatening injuries.
Start up procedure:
Give power to control board. Display shows “S0”, monitoring of the sensor not working
(solo per versione preserie).
11. Display will show E1 blinking.
Press “–“until display shows LP”, then press ENT until the display shows “—".