Manual ECC-DFC field bus controller
57
Figure 31 Example of a module diagnosis window
[1]
Sensor status OFF means sensor is clear; ON means sensor is blocked
[2]
Status of local upstream/downstream zone
[3]
Status of zone upstream of module -“ means that no connection is config-
ured
[4]
Status of zone downstream of module
[5]
Current status of connected motor the current strength, motor type, and
direction of rotation are displayed. Note that a red “!” means that no motor
current is present at the module
[6]
No motor connection in this example the module is configured so that it
has 2 zones and 2 motors, but the connection to the motor of the down-
stream zone has been interrupted, which is indicated by a red “X”