Auto configuration of the linear conveyor
Manual – ECC-DFC field bus controller
7.6. Results of auto configuration
7.6.1. Normal results
When the auto configuration procedure is complete, each module of the fieldbus
controller is automatically restarted. If a module has been successfully configured
and has been restarted, its module status LED flashes in green.
INFORMATION
Note that the duration of the auto configuration depends on the number of mod-
ules to be configured. It takes longer to configure bigger networks than smaller
networks.
The topology view shows the detailed information of the module in black text (no
longer red) when the auto configuration has been successfully completed; see
figure 24.
Figure 24 Auto configuration successful
If all module status LEDs flash in green, a load is placed in the zone that is fur-
thest upstream in order for complete verification of the configuration: If the auto
configuration was successful, the load is transported to the discharge zone. If this
does not occur, you can look up possible errors and the remedying thereof in
chapter “Problem solution for failed auto configuration”.