ECShell engineering software
Manual ECC-DFC field bus controller
77
INFORMATION
The following example requires the PC to have access to several subnetworks.
More information can be found under Appendix B configuring the PC for Ether-
net subnetworks.
Configuring node 192.168.27.25
1. First enter the correct subnetwork into the “Network IP” fields in the main window, plus
the correct node that you would like to connect. In this case, xxx.xxx.xxx.25 is node 6
for this special subnetwork.
2. Call up the Advanced Dialog and select the “Connections” tab.
Note that the relevant node is displayed in the middle and that this field is
deactivated. In addition, the designation “None” is displayed under “Downstream”.
The downstream flow should then be changed to IP address 192.168.25.20,
which is the next downstream node.
3. Click the button for the IP address, enter the correct value, and click the “Apply”
button.
Note that it takes about 20 seconds for the module to accept the change. The
module is then automatically restarted.