2
Interface box
Electrical installation
Addendum to the Operating Instructions – MOVIPRO
®
– Accessories
16
2.8.4 X1 terminal strip of the interface box
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
VO24
DGND
+24V_C
0V24_C
HT1
HT2
L1
L2
L3
VO24
DGND
+24V_C
0V24_C
HT1
HT2
L1
L2
L3
27021599719541387
Terminal strip X1 (power input terminal strip) Terminal cross
section
Name Function
[1] VO24 DC24Voutput 0.2–6mm
2
[2] GND Reference potential/DC24V output
[3] +24V_C DC 24 V input
[4] 0V24_C 0V24 reference potential – input
[5] HT1 Auxiliary terminal for additional voltage levels
(without internal function)
[6] HT2 Auxiliary terminal for additional voltage levels
(without internal function)
[7] L1 Supply system phase 1 0.2–10mm
2
[8] L2 Supply system phase 2
[9] L3 Supply system phase 3
[10] PE PE connection