EasyManua.ls Logo

Sharp AR-M256 - STAPLE JAM REMOVAL; CHECKING THE TONER QUANTITY AND TOTAL COUNT

Sharp AR-M256
159 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 33
Operation/procedure
Enter the set value with the 10-key, and press the [START] key.
Operation/procedure
1. Select an item with 10-key, and press [START] key.
2. Enter the setting value, and press [START] key.
Operation/procedure
1. Select an item with 10-key, and press [START] key.
2. Enter the setting value, and press [START] key.
Operation/procedure
The following data are displayed.
44
44-1
Purpose Setting
Function
(Purpose)
Used to make various setups in each mode of process
control.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Item Content Default
1
ENVIRONMENT
ADJ.
Environmental correction Allow/
Inhibit (0: Inhibit, 1: Allow)
1
2 DUPLEX PRINT ADJ.
Duplex print correction Allow/
Inhibit (0: Inhibit, 1: Allow)
0
44-2
Purpose Setting
Function
(Purpose)
Used to set the drum count correction.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Item Content Default
1 DRUM ADJUST
Drum count correction
Disable/Enable
(0: Disable, 1: Enable)
0
2
DRUM COUNT
(31)
The drum count value is set
for the LD power for 31 sheet
model.
(Setting in the unit of 1K)
(Setting range: 1-100)
100
3
DRUM COUNT
(25)
The drum count value is set
for the LD power for 25 sheet
model.
(Setting in the unit of 1K)
(Setting range: 1-100)
75
SIMULATION 44-02
44-3
Purpose Setting
Function
(Purpose)
Used to set the DV count correction.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Item Content Default
1 DV ADJUST
DV count correction Disable/
Enable
(0: Disable, 1: Enable)
0
2 DV COUNT (31)
The DV count value is set for
correction of the Grid/DVB
voltage. (31 sheet model)
(Setting in the unit of 1K)
(Setting range: 1-100)
100
3 DV COUNT (25)
The DV count value is set for
correction of the Grid/DVB
voltage. (25 sheet model)
(Setting in the unit of 1K)
(Setting range: 1-100)
75
44-9
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
(Purpose)
Used to display the process control correction
information.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Item Content
Default
25cpm 31cpm
DRUM ADJUST
Drum count correction state
(0:OFF, 1:ON) *
00
DV ADJUST
DV count correction state
(0:OFF, 1:ON) *
00
TH AREA1
Current correction value of the
environment correction area 1
(Grid/DVB correction)
76 126
TH AREA2
Current correction value of the
environment correction area 2
(Grid/DVB correction)
26 76
TH AREA3
Current correction value of the
environment correction area 3
(Grid/DVB correction)
00
TH AREA4
Current correction value of the
environment correction area 4
(Grid/DVB correction)
00
SIMULATION 44-03

Table of Contents

Other manuals for Sharp AR-M256