AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 46
Operation/procedure
Select the set value with the 10-key.
Operation/Procedure
1. Touch the item to be adjusted.
The item and the currently set value are highlighted.
2. Enter the set value with the 10-key.
Operation/Procedure
(Max. position setting)
1. Set the guide to the maximum position, and press the [START] key.
Set WLetter and fit the guide, and press the [START] key.
2. Set A4R/Letter R and fit the guide, and press the [START] key.
3. Set A5R/Invoice R and fit the guide, and press the [START] key.
4. Set the guide to the minimum position, and press the [START] key.
5. Set the paper recognition width (+), and press the [START] key.
6. Set the paper recognition width (–),and press the [START] key.
If “FAILED” is displayed in the above procedure 1, 2, 3, or 4, repeat the
adjustment.
(Middle position L/S setting)
If the middle position adjustment is not required, press the [START] key
without changing the guide position.
Operation/Procedure
1. Touch the item to be adjusted.
The item and the currently set value are highlighted.
2. Enter the RSPF original tray size adjustment value (specified on
the back of the RSPF) with the 10-key.
51-8
Purpose Setting
Function
(Purpose)
Used to set the OPC drum separation pawl operation
inhibit. (ON/OFF)
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Item Content Setting range Default
0
ON
Enable
0-1 0
1
OFF
Disable
51-9
Purpose Setting
Function
(Purpose)
Used to adjust the OPC drum separation voltage ON/
OFF timing.
Section Process (OPC drum, developing, transfer, cleaning)
Item Operation
Item Content
Setting
range
Default
1SHV ON
Separation voltage ON timing
* Transfer V2ON reference
(Synchronized with the
adjustment value of 50.)
25-90 50
2SHV OFF
Separation voltage OFF timing
* Transfer V2OFF reference
(Synchronized with the
adjustment value of 50.)
50-90 75
53
53-6
Purpose Adjustment
Function
(Purpose)
Used to adjust the detection level of the RSPF width.
The adjustment method is the 4-point system. Set the
guide to Max. (A3/WLetter) position, A4R/Letter R
position, A5R/Invoice R position, and Min. position for
adjustment.
Section RSPF
Middle position
adjustment L
YES MID-L ADJ.ON
NO MID-L ADJ.OFF
Middle position
adjustment S
YES MID-S ADJ.ON
NO MID-S ADJ.OFF
AB series Inch series
53-7
Purpose Adjustment
Function
(Purpose)
Used to enter the RSPF width detection adjustment
value.
Section RSPF
Item Content Setting range Default
1 MAX POSITION Max. width
0-999 0
2 POSITION 1 Adjustment point 1
3 POSITION 2 Adjustment point 2
4 MIN POSITION Min. width