22
CHAPTER 1
[C FSE]: Used to set the display method of calculation results (default setting: FloatPt)
[1 FloatPt]: Floating point method
[2 Fix]: Fixed decimal point method
[3 Sci]: Exponential method (✳✳✳E
✳✳
)
[4 Eng]: Engineers exponential method (exponentials are in multiples of 3:
✳✳✳E
✳✳
)
multiples of 3
In [2 Fix], [3 Sci], and [4 Eng], the answer displays using the number of decimals set by
TAB.
CAUTION
When FloatPt is selected in this menu, FloatPt is given priority even if the number of decimals
is specified in [D TAB], which is described later.
[D TAB]: Specifies the number of decimals (default setting: 9).
TAB 0 to 9 can be set from submenu options.
<Example>
Set to TAB 2 in the Sci mode then execute “1 ÷ 3”.
1. Press
¬
.
Clear the display screen completely.
2.
Press
Ï
.
3. Press
C
or touch [C FSE] using the touch-pen.
4. Touch [3 Sci].
Now the method for displaying results is set.
5. Press
D
or
touch [D TAB].
6. Touch [2 2].
7. Return to the normal function calculation screen by
pressing
.
8. Press 1
/
3
®
.
[E COORD]: Used to set the coordinate system of
graphs (default setting: Rect)
[1 Rect]: Rectangular coordinates
[2 Param]: Parametric equation coordinates
[3 Polar]: Polar coordinates
[4 Seq]: Sequential graph coordinates
EL-9650-(01)En (001-036) 8/1/00, 12:04 PM22