EasyManua.ls Logo

Sharp er-3100 - Remote Drawer Operational Check

Sharp er-3100
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(5)
(6)
the table because the adhesive area may accidentallycontact
it.
Also clean the surface of the table.
Stand the drawer up, and gently press it down to fix the
adhesive face of each fixture firmly on the table.
(See
Fig. 20)
Now the drawer has been fixed tightly to the table.
In case
you want to remove the drawer to another location,move it
to the left (lookingfrom the front) to detach it from the
fixtures. The balancingmetal fixture loses its adhesive
properties once used.
9.3 Operationalcheck
Execute the drawer test in the SRV mode.
Job numbers 111 and 112
With this key operation a single drawer alone opens; and a ~
appears in the first position of the register display if the
drawer is provided with the drawer open sensor.
(If not, a [
appears.
The main drawers of those machines for some general
agents are providedwith no drawer open sensor.)
Close the open drawer by hand.
Then the O
is replacedwith a
II[ ft
. (If the drawer is providedwith no drawer open sensor,
the
II[ 11
in the display remains unchangedwhen the drawer is
closed.)
After confirmingthe above drawer and display actions press a key
on the keyboard.
This will provide the “Check over” print and
then finalize the drawer test.
Table 19
11X
I
Job #
Drawer to work
111 Main drawer (Drawer 1)
Sample“Checkovert’print
(X: 1 or 2)
112 Remote drawer (Drawer 2)
–52–