Note:
The associated department is changed if the operator depress
[DPTn] key instead of [PLUn] key by mistake at this program-
ming step.
Triple depression of the [PLU] or [PLUn] key is necessary for the
first entry.
7) PROGRAMMING OF PLU/SUBDEPT
Mode : PGM2
XXXXXX: PLU CODE (1 to 999999)
A: Sign A
+0
–1
B: Food stamp B
Non-food stampable 0
Food stampable 1
C: Taxable4 C
Non taxable 0
Taxable 1
D: Taxable3 D
Non taxable 0
Taxable 1
E: Taxable2 E
Non taxable 0
Taxable 1
F: Taxable1 F
Non taxable 0
Taxable 1
G: Amount entry type G
Inhibited 0
Open 1
Preset 2
Open and preset 3
Delete 4
If the record of the entered PLU code is not in the PLU file at this
programming step, the PLU code will be created.
MRS = 002
*
If the [PLU] or [PLUn] key is depressed, the programming mode
is changed from the "PRICE PROGRAMMING" to "ATTRIBUTE
PROGRAMMING" and then changed to the "PLU ASSOCIA-
TION PROGRAMMING" by depressing the same key again.
Double depression of [PLU] or [PLUn] key is necessary for the
first time.
8) UPC PRESET PRICE SETTING
Mode:PGM1/PGM2
XXXXXXXXXXXXX: UPC code
YYYYYY: Unit price (6 digits)
If the record of the entered UPC code is not in the UPC file at this
programming step, the UPC code will be created.
MRS = Nothing (Default = 0)
The default value is set when the new UPC record is created.
At this time, Price1 is shown.
If the [UPC] key is depressed, the programming mode is changed
from "PRICE PROGRAMMING" to "ATTRIBUTE PROGRAM-
MING" and then changed to the "UPC ASSOCIATION PRO-
GRAMMING" by depressing the same key again.
9) PROGRAMMING OF UPC
Mode : PGM2
XXXXXXXXXXXXX: UPC code
A: Sign A
+0
-1
B: Food stamp B
No 0
Yes 1
C: Taxable4 C
Non taxable 0
Taxable 1
D: Taxable3 D
Non taxable 0
Taxable 1
E: Taxable2 E
Non taxable 0
Taxable 1
F: Taxable1 F
Non taxable 0
Taxable 1
G: Record delete method G
Delete at X/Z non-accessed
UPC deleting JOB
0
Non delete 1
Delete now 2
If the record of the entered UPC code is not in the UPC file at this
programming step, the UPC code is created.
MRS = nothing ( Default = 0000000)
The default value is set when the new UPC record is created.
Not changed
XXXXXX
PLU code
for next code
ABCDEFG
@/FOR
CA/AT
PLU
PLUn
XXXXXXXXXXXXX
UPC
(Scanning)
YYYYYY
No change
P1
CA/ATSBTL
P2
P3
(Pricel shift)
(Pricel)
XXXXXXXXXXXXX UPC
(Scanning)
ABCDEFG
No change
CA/AT@/FOR
UPC code