Many electrical and mechanical parts in LCD television have special safety-related characteristics.
These characteristics are often not evident from visual inspection, nor can protection afforded by them be necessarily
increased by using replacement components rated for higher voltage, wattage, etc.
Replacementpartswhichhavethesespecialsafetycharacteristicsareidentiedinthismanual;electricalcomponents
havingsuchfeaturesareidentiedby““.
For continued protection, replacement parts must be identical to those used in the original circuit.
The use of a substitute replacement parts which do not have the same safety characteristics as the factory recommended
replacementpartsshowninthisservicemanual,maycreateshock,reorotherhazards.
IMPORTANT SERVICE SAFETY PRECAUTION
Service work should be performed only by qualied service technicians who are thoroughly familiar with all
safety checks and the servicing guidelines which follow:
WARNING
1.Forcontinuedsafety,nomodicationofanycircuitshouldbeattempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)
Before returning the receiver to the user, perform the following safety checks:
1. Inspect all lead dress to make certain that leads are not pinched, and check that hardware is not lodged between the
chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic control knobs, insulation materials, cabinet backs, adjustment and
compartment covers or shields, isolation resistor-capacitor networks, mechanical insulators, etc.
3.Tobesurethatnoshockhazardexists,checkforleakagecurrentinthefollowingmanner.
• Plug the AC cord directly into a 220~240 volt AC outlet. (Do not use an isolation transformer for this test).
•Usingtwoclipleads,connecta1.5kohm,10wattresistorparalleledbya0.15µFcapacitorinserieswithallexposedmetal
cabinet parts and a known earth ground, such as electrical conduit or electrical ground connected to an earth ground.
•AtrueRMSreadingmultimetershouldbeusedforthistest,especiallywheretheequipmentusesaswitchmode
power supply which may result in very non-sinusoidal leakage current.
•Connecttheresistorconnectiontoallexposedmetalpartshavingareturntothechassis(antenna,metalcabinet,
screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor.
AllchecksmustberepeatedwiththeACcordplugconnectionreversed.(Ifnecessary,anonpolarizedadaptorplugmust
be used only for the purpose of completing these checks.)
Anyreadingof1.05Vpeak(thiscorrespondsto0.7mA.peakAC.)ormoreisexcessiveandindicatesapotentialshock
hazardwhichmustbecorrectedbeforereturningthemonitortotheowner.
!
CAUTION: FOR CONTINUED PROTECTION AGAINST A RISK OF
FIRE REPLACE ONLY WITH SAME TYPE F101 (T4 AH / 250V)