MX-5001N MAINTENANCE 8 – 45
9) Remove the cleaner.
10) Use the cleaner to clean the scanning glass (surface).
Maintenance: Clean at every 150K.
11) Use the cleaner to clean the white reference glass.
Maintenance: Clean at every 150K.
12) Close the DSPF unit. Open the upper door, and remove the
screw.
13) Remove the pawl, and remove the front cabinet.
14) Remove the screw. Remove the pawl. Remove the rear cabi-
net.
15) Open the DSPF unit, and remove the OC mat from the left
edge.
Maintenance: Clean at every 150K.
* When assembling, place the OC mat on the document table
to fit with the reference and close the DSPF unit.