MX-5001N ELECTRICAL SECTION 10 – 42
CSS12 Tray 1 paper size detection 2 Tray 1 paper size detection 2 YES NO CN9 29 PCU
CSS13 Tray 1 paper size detection 3 Tray 1 paper size detection 3 YES NO CN9 31 PCU
CSS14 Tray 1 paper size detection 4 Tray 1 paper size detection 4 YES NO CN9 33 PCU
CSS21 Tray 2 paper size detection 1 Tray 2 paper size detection 1 YES NO CN9 28 PCU
CSS22 Tray 2 paper size detection 2 Tray 2 paper size detection 2 YES NO CN9 30 PCU
CSS23 Tray 2 paper size detection 3 Tray 2 paper size detection 3 YES NO CN9 32 PCU
CSS24 Tray 2 paper size detection 4 Tray 2 paper size detection 4 YES NO CN9 34 PCU
DHPD_C C phase detection Detects the C phase. Reference CN11 20 PCU
DHPD_K BK phase detection Detects the BL phase. Reference CN11 17 PCU
DHPD_M M phase detection Detects the M phase. Reference CN11 23 PCU
DHPD_Y Y phase detection Detects the Y phase. Reference CN11 26 PCU
DL_BK Discharge lamp BK [LED] Discharges electric charges on
the OPC drum.
OFF ON CN10 1 PCU
DL_C Discharge lamp C [LED] Discharges electric charges on
the OPC drum.
OFF ON CN10 21 PCU
DL_M Discharge lamp M [LED] Discharges electric charges on
the OPC drum.
OFF ON CN10 2 PCU
DL_Y Discharge lamp Y [LED] Discharges electric charges on
the OPC drum.
OFF ON CN10 22 PCU
DM_CL_
CNT
Drum motor (CL) current
select
Selects the drum motor (CL)
current.
Large
current
Small
current
CN12 1 PCU
DM_K_
CNT
Drum motor (K) current select Selects the drum motor (K)
current.
Large
current
Small
current
CN12 11 PCU
DSW_
ADU
ADU transport open/close
detection [Transmission type]
Detects open/close of the ADU
cover.
Open Close CN2 7 RD I/F
DSW_C Tray 1, 2 transport cover open/
close detection
Detects open/close of the tray 1,
2 transport cover.
Open Close CN8 28 PCU
DSW_F Front door open/close switch
[Micro switch]
Detects open/close of the front
door, and fusing, motor, LSU
laser power line.
Open Close CN17 4 PCU
DSW_R Right door open/close switch
[Micro switch]
Detects open/close of the right
door unit, and fusing, motor, LSU
laser power line.
Open Close CN17 2,3 PCU
DVM_CL_
D
Development drive motor (CL)
[Brushless motor]
Drives the development section,
the color OPC drum, and the
transfer section.
Drive Stop CN11 12 PCU
DVM_CL_
LD
Development drive motor (CL)
lock detection
Detects the development drive
motor (CL) lock.
Lock
detection
CN11 14 PCU
DVM_K_D Development drive motor (K)
[Brushless motor]
Drives the development section,
the black OPC drum, and the
transfer section.
Drive Stop CN11 11 PCU
DVM_K_
LD
Development drive motor (K)
lock detection
Detects the development drive
motor (K) lock.
Lock
detection
CN11 13 PCU
FUFM_LD Fusing fan motor lock
detection
Detects the fusing fan motor
lock.
Lock
detection
CN13 34 PCU
FUFM_V Fusing fan motor Cools motor related to the fusing
section and paper exit section.
OFF ON CN13 33 PCU
FUM_D Fusing motor
[Brushless motor]
Drives the fusing unit. Drive Stop CN14 29 PCU
FUM_LD Fusing motor lock detection Detects the fusing motor lock. Lock
detection
CN14 31 PCU
HLOUT_
EX
Heater lamp external Turns ON/OFF the heater lamp
external.
OFF ON CN14 12 PCU
HLOUT_
LM
Heater lamp lower main Turns ON/OFF the heater lamp
lower main.
OFF ON CN14 10 PCU
HLOUT_
UM
Heater lamp upper main Turns ON/OFF the heater lamp
upper main.
OFF ON CN14 14 PCU
HLOUT_
US
Heater lamp upper sub Turns ON/OFF the heater lamp
upper sub.
OFF ON CN14 8 PCU
HLPCD Fusing pressure detection
sensor [Transmission sensor]
Detects a change in the fusing
pressure.
Pressure
release
Pressure
applying
CN14 30 PCU
HPFM Horizontal transport motor
[Stepping motor]
Transports paper from the paper
feed section to the transport
motor drive system.
Transports paper from the right
door section to the transport
motor drive system.
CN8 6,8,
10,12
PCU Drives with the
4-phase signal.
HPFM_
CNT
Horizontal transport motor Selects the horizontal transport
motor current.
Large
current
Small
current
CN8 4 PCU
HPOS Shifter home position detection Detects the shifter home
position.
–Home
position
CN13 28 PCU
HUD_M Humidity detection Detects the humidity. CN7 8 PCU Analog
detection
Signal
name
Name [Type] Function/Operation
Connector level
Connector
No.
Pin
No.
PWB
name
NOTE
"L" "H"