MX-M350/M450 N/U SIMULATION 9 - 14
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
Set range of interval time: 1 - 999 (sec)
Set the intermittent aging mode cycle of 7-1 with 10-key. (Unit:
sec)
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1)
is set.
The setting of this simulation is kept valid until the power is
turned off.
The warm-up time is displayed in the unit of second.
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The developing bias output voltage adjustment and output check
can be made in each print mode.)
7-6
Purpose Setting
Function
(Purpose)
Used to set the intermittent aging cycle.
Section
Item Operation
7-8
Purpose Setting
Function
(Purpose)
Used to set the warm-up time display YES/NO.
Item Operation
Warm-up is completed. Press [SYSTEM SETTINGS] key.
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key,
and time count is started.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
Press [SYSTEM SETTINGS] key,
and time count is stopped.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60
8
8-1
Purpose Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operations of the
developing voltage of each color and the control
circuit.
Section Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Set
range
Default
MX-
M350
MX-
M450
1 AUTO Auto mode 0 - 745 455 485
2 CHARACTER Text mode 485 485
3 MIX Text/Photo mode
4 PHOTO Photo mode
5 PRINTER Printer mode
6 FAX FAX mode
7 PLUS Reverse developing
bias voltage
0 - 255 150 150
Press [START] key. Press [SYSTEM SETTINGS] key.
Press [START] key. Press [SYSTEM SETTINGS] key.
Or after 30sec output.
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO 485 2.CHARACTER 485
3.MIX 485 4.PHOTO 485
5.PRINTER 485 6.FAX 485 7.PLUS 150
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-745)
485
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
485