EasyManua.ls Logo

Sharp MX-M350 - Page 173

Sharp MX-M350
276 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-M350/M450 N/U SIMULATION 9 - 34
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
Operation/Procedure
When bit =1, correction is made.
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
*1: Only when this value is 0, control is made with the actual mea-
surement value of the process thermistor (temperature/humid-
ity). When it is not 0, control is made with the forcible setting
value.
43
43-1
Purpose Setting
Function
(Purpose)
Used to set the fusing temperature in each
operation mode.
Section Fixing (Fusing)
Item Operation
Item Default
1 INSIDE NORMAL Heater inside/normal 190
2 OUTSIDE NORMAL Heater outside/normal 190
3 INSIDE PREHEAT Heater inside/preheat 150
4 OUTSIDE PREHEAT Heater outside/preheat 150
Press [START] key. Press [SYSTEM SETTINGS] key.
44
44-1
Purpose Setting
Function
(Purpose)
Used to set enable/disable of correction
operations in the image forming (process) section.
Section Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item Operation
Bit1514131211109876543210
00000000
Vg4
Vb4
Ld4
Vbr
Vg3
Vb3
Ld3
Vb1
Vb2
Ld2 Vg2 Ld1 Vg1
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200 PD2[128]: 200
PD3[128]: 50 PD4[128]: 52
PD5[128]: 51 PD6[128]: 50
PD7[128]: 52
SIMULATION 43-1
1
FUSER TEMPERATURE SET. SELECT 1-4, AND PRESS START.
1. INSIDE NORMAL 190
2. OUTSIDE NORMAL 190
3. INSIDE PREHEAT 150
4. OUTSIDE PREHEAT 150
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
190
44-4
Purpose Setup
Function
(Purpose)
Used to set the target image (reference) density
level in the developing bias voltage correction.
Section Process
(Photoconductor/Developing/Transfer/Cleaning)
Item Data
Item
1 TEMP. AREA *1 Process environment temperature
forcible setting value
(0 - 13 /normal: 0)
2 HUMIDITY AREA *1 Process environment humidity
forcible setting value
(0 - 14 /normal: 0)
3 S_WT Vb rising correction standby time
(0 - 180 sec/default: 90)
4 Vb1 Vb correction amount (first rotation)
(0 - 150V/default: 50)
5 Vb2 Vb correction amount (second
rotation) (0-50V/default: 15)
Press [START] key. Press [SYSTEM SETTINGS] key.
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-255
AND PRESS START.
BIT0:Vg1, BIT1:Ld1, BIT2:Vg2, BIT3:Ld2
BIT4:Vb1, Vb2
BIT5:Vg3, Vb3, Ld3
BIT6:Vbr
BIT7:Vg4, Vb4, Ld4
111
SIMULATION 44-4
3
PROCESS CONTROL VALUE SETTING. SELECT 1-5 AND PRESS
START.
1.TEMP. AREA 0
2.HUMIDITY AREA 0
3.S_WT 90
4.Vb1 50
5.Vb2 15
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
3.S_WT
90