30
PG-C30XU
No. Adjusting point Adjusting conditions Adjusting procedure
30 RGB
performance
check
1. Receive the RGB signal. » In the process mode and select L4. Check the pic-
ture, brightness, red, blue, clock, phase, horizontal
position, and vertical position.
31 Off-timer
performance
check
» In the process mode and select OFF. Make sure that
the off-timer starts with “5” (minutes), counts down
each minute in 1 second, and turns off the set at “0”.
32 Thermistor
performance
check
1. Heat the thermistor using a
dryer.
» Make sure the “TEMP” is displayed.
S4 “Factory setting 4”
Remote controller
setting
Process
adjustment
» Make the following settings.35 Factory settings
33 Automatic
synchronization
1. Receive the PHASE check
pattern signal.
» Call the VGA/SVGA/XGA/SXGA mode and make
sure that the clock, phase, horizontal and vertical
positions can be automatically adjusted.
34 Keystone
correction
performance
check
» Make sure the keystone correction functions well.