Service and Maintenance Manual 3-136 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
S
TRIPPER PLATE SENSORS (con’t)
3. Locate the PLC. While watching the inputs
labeled ‘X1’ and ‘X6”, depress each side of the
stripper plate. When pressing the left side of
the stripper plate, the input light for ‘X1” should
turn on. When pressing the right side of the
plate, the input light for ‘X6’ should light up. If
the PLC does not illuminate when either sensor
is activated, the sensor is faulty and needs
replacement (Figure 3-344).
1. Move the pressure bar inward, and place the
two seal wire changing tools between the face
plate and the pressure bar approximately 2”
from each end (Figure 3-345).
2. Move the left and right sensors all the way
towards the front of the machine.
3. Slide left sensor bracket back until light X1 on
the PLC turns on, and secure in place
4. Slide the right sensor bracket back until light
X6 on the PLC turns on, and secure in place.
Always remove electrical power from the
SX
prior to performing any maintenance
and ‘X6’
Figure 3-345. Stripper Plate Positioning for
Jaw Sensors