Picture 4-8Weekly Time Start Setup 5
5. F-05 stands for the function of temperature protection. Alarm will be launched
if actual temperature were equal to or higher than the addition of setting
temperature value and setting value. This temperature range is between 0 to
50, and default value is 15.
4.6 Present Time Modification
1) Repeat the above steps until PV displays "TIME" to stand for present time.
2) Press key to add or decrease time.
3) Press "ENTER" key and PV displays "DAY" to stand for week days.
4) Press key to add or decrease days.
5) Press "SET" key to back to normal status after finish all the setup.
4.7 Weekly Time Start
1) Activate the weekly time start after finish the time setup and the present time
setup.
2) Press "AUTO" key at working or stop status to preset the time start/stop, the
"PV" will display the time and temp. alternatively.
3) Press "AUTO" again if want to cancel that weekly time setup.
4.8 Lock Setup Way
1) Press "SET" key down and release it till "PV" displays F-20.
2) Press key to make "SV" to 0021, then press "ENTER" keythe "PV"