EasyManua.ls Logo

Shure ANIUSB-Matrix - IP Ports and Protocols

Shure ANIUSB-Matrix
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shure Incorporated
25/32
Latency Setting Maximum Number of Switches
1 ms 10
2 ms 10+
IP Ports and Protocols
Shure Control
Port TCP/UDP Protocol Description
Factory De-
fault
21 TCP FTP Required for firmware updates (otherwise closed) Closed
22 TCP SSH Secure Shell Interface Closed
23 TCP Telnet Not supported Closed
53 UDP DNS Domain Name System Closed
67 UDP DHCP Dynamic Host Configuration Protocol Open
68 UDP DHCP Dynamic Host Configuration Protocol Open
80* TCP HTTP Required to launch embedded web server Open
443 TCP HTTPS Not supported Closed
2202 TCP ASCII Required for 3rd party control strings Open
5353 UDP mDNS Required for device discovery Open
5568 UDP SDT (multicast) Required for inter-device communication Open
57383 UDP SDT (unicast) Required for inter-device communication Open
8023 TCP Telnet Debug console interface Closed
8180 TCP HTML Required for web application (legacy firmware only) Open
8427 UDP SLP (multicast) Required for inter-device communication Open
64000 TCP Telnet Required for Shure firmware update Open
*These ports must be open on the PC or control system to access the device through a firewall.
These protocols require multicast. Ensure multicast has been correctly configured for your network.
See Audinate's website for information about ports and protocols used by Dante audio.