Latency Setting Maximum Number of Switches
1 ms 10
2 ms 10+
Connecting to an External Control System
The MXW System connects to an AMX or Crestron control system via the Ethernet. Use only one controller per system to
avoid messaging conflicts. For a comprehensive list of MXW command strings, visit: http://shure.custhelp.com/app/answers/
detail/a_id/5207
Connection: Ethernet (TCP/IP; MXW is the client)
Port: 2202
IP Ports and Protocols
Shure Control
Port TCP/UDP Protocol Description
Factory De
fault
21 tcp FTP Required for firmware updates (otherwise closed) Closed
68 udp DHCP Dynamic Host Configuration Protocol Open
80* tcp HTTP Required to launch embedded web server Open
427 tcp/udp SLP Required for inter-device communication Open
843* tcp Flash Required for web application Open
2202 tcp ASCII Required for 3rd party control strings Open
5353 udp mDNS Required for device discovery Open
5568 udp SDT Required for inter-device communication Open
8180* tcp Flash Required for web application Open
8181* tcp Flash Required for web application Open
8427 udp Multcast SLP Required for inter-device communication Open
64000 tcp Telnet Required for Shure firmware update Open
Dante Audio & Controller
Port TCP/UDP Protocol Description
[319-320]* udp PTP Dante clocking
4321,
14336-14600
udp Dante Dante audio
[4440, 4444,
4455]*
udp Dante Dante audio routing
†
†
†
†
†