Command String:
< GET x ALL >
Where x is ASCII channel number: 0
through 5. Use this command on
first power on to update the status of
all parameters.
MXA310 Response:
< REP ... >
The MXA310 responds with individ
ual Report strings for all parameters.
Get Model Number
Command String:
< GET MODEL >
MXA310 Response:
< REP MODEL {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >
Where
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
is 32 characters of the model num
ber. The MXA310 always responds
with a 32 character model number.
Get Serial Number
Command String:
< GET SERIAL_NUM >
MXA310 Response:
< REP SERIAL_NUM {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >
Where
yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy
is 32 characters of the serial num
ber. The MXA310 always responds
with a 32 character serial number.
Get Firmware Version
Command String:
< GET FW_VER >
MXA310 Response:
< REP FW_VER {yyyyyyyyyyyyyyyyyy} >
Where yyyyyyyyyyyyyyyyyy is 18
characters. The MXA310 always re
sponds with 18 characters.
Get Audio IP Address
Command String:
< GET IP_ADDR_NET_AUDIO_PRIMARY >