Get Error Events (firmware > v2.0)
Command String:
< GET LAST_ERROR_EVENT >
MXA310 Response:
< REP LAST_ERROR_EVENT {yyyyy} >
Where yyyy can be up to 128 char
acters.
Get Low Cut Filter (firmware > v2.0)
Command String:
< GET LOW_CUT_FILTER >
MXA310 Response:
< REP LOW_CUT_FILTER ON >
< REP LOW_CUT_FILTER OFF >
The MXA310 will respond with one
of these strings.
Set Low Cut Filter (firmware > v2.0)
Command String:
< SET LOW_CUT_FILTER ON >
< SET LOW_CUT_FILTER OFF >
< SET LOW_CUT_FILTER TOGGLE >
Send on of these commands to the
MXA310
MXA310 Response:
< REP LOW_CUT_FILTER ON >
< REP LOW_CUT_FILTER OFF >
The MXA310 will respond with one
of these strings.
Get PEQ Filter Enable (firmware > v3.0)
Command String:
< GET xx PEQ yy >
Where xx is the PEQ block 01-04 on
mic channel. 5 is the PEQ on the
automix out channel. Where yy is
the PEQ filter 0104 within the se
lected block. 00 can be used for all
blocks or all filters.
MXA310 Response:
< REP xx PEQ yy ON >
< REP xx PEQ yy OFF >
Set PEQ Filter Enable (firmware > v3.0)