Shure Incorporated
58/76
Increment/Decrement Lobe Angle (firmware > v2.0)
Command String:
< SET x LOBE_ANGLE INC nn >
< SET x LOBE_ANGLE DEC nnn >
Send one of these strings to the
MXA310. Where nn is 15, 30, 45,
60, etc.
MXA310 Response:
< REP x LOBE_ANGLE nnn >
Where nnn is 015, 030, 045, 060,
075, 090, 105, 120, 135, 150, 165,
180, 195, 210, 225, 240, 255, 270,
285, 300, 315, 330, or 345.
Set Lobe Angle (firmware > v2.0)
Command String:
< SET x LOBE_ANGLE nn >
MXA310 Response:
< REP x LOBE_ANGLE nnn >
Where nnn is 015, 030, 045, 060,
075, 090, 105, 120, 135, 150, 165,
180, 195, 210, 225, 240, 255, 270,
285, 300, 315, 330, or 345.
Get Mute Control Function (firmware > v2.0)
Command String:
< GET MUTE_CONTROL_FUNC >
MXA310 Response:
< REP MUTE_CONTROL_FUNC LOCAL >
< REP MUTE_CONTROL_FUNC LOGIC >
< REP MUTE_CONTROL_FUNC DISABLED >
The MXA310 will respond with one
of these strings.
Set Mute Control Function (firmware > v2.0)
Command String:
< SET MUTE_CONTROL_FUNC LOCAL >
< SET MUTE_CONTROL_FUNC LOGIC >
< SET MUTE_CONTROL_FUNC DISABLED >
Send on of these commands to the
MXA310
MXA310 Response:
< REP MUTE_CONTROL_FUNC LOCAL >
< REP MUTE_CONTROL_FUNC LOGIC >
< REP MUTE_CONTROL_FUNC DISABLED >
The MXA310 will respond with one
of these strings.