Minimum Typical Maximum
Cable material of the system connec‐
t
ion
PVC
Ambient operating temperature
3)
4)
0 °C +55°C
Air humidity (non-condensing) 15% 95%
Storage temperature -30°C +70°C
Housing cross-section 38.7mm × 45.6mm, plus bracket, see "Dimensional
dr
awings", page 61
Vibration resistance
5)
5…150Hz, 3,5mm/1g (EN 60068-2-6)
Shock resistance
6)
15g/6ms (EN 60068-2-27)
Class 3M4 (IEC TR 60721-4-3)
1)
The connecting cables used must be suitable for the specific explosion-hazardous area.
2)
Maximum permissible conductor resistance must be observed.
3)
The temperature difference between sender and receiver must not exceed 25K.
4)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25°C
.
5)
Test conditions per axis: 1octave/minute, 20 sweeps.
6)
Test conditions per axis: 200shocks.
12.2 Response time
Table 14: Response time dependent on the protective field height
Protective field height in mm Response time in ms
Resolution 14mm Resolution 30mm
300 11 10
450 12 10
600 13 10
750 13 11
900 14 11
1050 15 11
1200 16 12
1350 17 12
1500 18 13
1650 19 13
1800 20 13
1950 21 14
2100 22 14
12.3 Power consumption
Table 15: Power consumption for sender and receiver
Protective field
hei
ght in mm
Typical power consumption for
sender in W
Typical power consumption for
receiver in W
1)
Resolution
14mm
Resolution
30mm
Resolution
14mm
Resolution
30mm
300 0.96 0.82 1.92 1.63
450 1.08 0.86 2.16 1.73
600 1.20 0.91 2.40 1.82
750 1.32 0.96 2.64 1.92
TECHNICAL DATA 12
8021796/1DCM/2022-10-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Ex II 3GD
59
Subject to change without notice