b
Mak
e sure that the sender and receiver are aligned correctly. The optical lens
systems of the sender and the receiver must be located opposite one another (5).
b If nece
ssary, use a spirit level to check that the components are parallel (6).
Further topics
•
"Minimum dis
tance from the hazardous point", page 17
•
"Minimum distance to reflective surfaces", page 20
•
"Sender and receiver alignment", page 45
•
"Alignment with the QuickFix bracket", page 47
•
"Alignment with the FlexFix bracket or with the upgrade bracket", page 47
5.2.1 Mounting the QuickFix bracket
Overview
2 Q
uickFix brackets are used to mount the sender and receiver.
The QuickFix bracket consists of 2 parts, which are pushed into each other. The two
individual parts are connected with an M5 screw and the housing (sender or receiver) is
clamped with form-fit clamping.
The two mounting surfaces for the brackets of the sender or receiver must be parallel
and lie in the same plane.
5 MOUN
TING
34
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Ex II 3GD 8021796/1DCM/2022-10-27 | SICK