Figure 21: Double safety-related zone
Figure 22: Observation window
Setting Description
Behavior of digital
output
The “Switching behavior” setting can be used to manually select whether
the output should relate to the Double safety-related Zone (see figure 21,
page 33) or Observation window (see figure 22, page 33).
When the switching behavior is changed, the values set for switching
point1 and switching point2 are automatically swapped by the device.
Switching point1
With the “Switching point1” setting, the first of the two switching
points of the switching window can be set manually in millimeters.
The first of the two switching points can be taught in for the Switching
window (Window mode) switching mode using the “Switching point1”
teach method.
For Double safety-related zone (see figure 21, page 33), “Switching point1”
must be taught in first, for Observation window (see figure 22, page 33),
“Switching point2” must be taught in first to avoid switching the behavior
twice during teach-in.