Loading...
Carry out a good teach-in for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Teach Q
1
→ Length of ref. object
/ to → Q
1
Good teach-in
ESC?
Move one or more good objects past the sensor
After the last good object → Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
Set the switching threshold for the shape comparison for Q
1
manually
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Manual Q
1
→ Q
1
Logic
/ to → Q
1
Tolerance
100 (Note: 1 = flashing 1)
/ , / , / to the → desired
switching threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
Set the shape of the trigger threshold for Q
1
manually
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/ to → Manual Q
1
→ Q
1
Logic
/ to → Q
1
Self trigger
00025 (Note: 0 = flashing 0)
/ , / , / , / ,
/ , / to → desired shape trigger
threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Factory setting:
-
OPERATION 6