For the output function Q
2
configure and activate /Q
a
through switching
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
→ 4 - 20 mA
/ to → Switching
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
4 - 20 mA
Select the “Shape” switching mode for Q
2
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
/ to → ModeQ
2
→ DtO (1point)
/ to → Shape
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= Switching
Factory setting:
-
Carry out a good teach-in for Q
2
Operating example or steps:
RUN mode
→ Q
1
Output
/ to → Q
2
Output
→ Function Q
2
/Q
a
/ to → Teach Q
2
→ Length of ref. object
/ to → Q
2
Good teach-in
→ ESC?
Move one or more good objects past the sensor
After the last good object → Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Output function Q
2
/Q
a
= switching
Mode Q
2
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
6 OPERATION
42
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro 8017154/1AVV/2021-03-24 | SICK