Non Hazard Area
EN 60079-14
24V DC +
24V Gnd
Explosion Hazard Location
F. R i ff e r
SICK Engineering GmbH
Bergenerring 27
01458 Ottendorf-Okrilla
Tel.: +(49) 35205 524 10
13.03.2013
Date
created
released
Standard
Date NameRev. ECN
Configuration: Flow-X/P1
Sheet 1
FLOWSIC 600
RS 485
Modbus
31+
32-
33+
34-
51+
52-
41+
42-
81+
82-
1 (+)
2 (-)
.
For further details see
!
WARNING!
Incorrect cabling may cause
operation manual of the
individual device.
RS485 Modbus - approx. impedance 120 Ohm
maximum length: 500 m
EC-Typ-Examination Certificate
For Safety/Entity - Parameters see
Compliance CSA 1298901
Certificate of Conformity
TÜV 01 ATEX 1766 X resp. Certificate of
Flowsic 600 Certificates
Network
SCADA
2x2x0,5 mm²
Li2YCYv(TP)
2x2x0,5 mm²
Li2YCYv(TP)
2x2x0,5 mm²
Li2YCYv(TP)
2x1,5 mm²
NYY-O
the devices to fail!
Flow computer Flow-X
2x1,5 mm²
NYY-O
Flow-X/P1
X1A
ETH 1 ETH 2
24 VDC
Power supply
0V
0V
+24V
TRx-
TRx+
+AI1
-AI1
+AI2
-AI2
Pressure
Temperature
(internally linked)
5-
6-
1
2
5
9
11
32
33
34
35
2+
1+
ProcessTransmitter
p
Pressure
PE
4...20 mA or HART
loop powered
T
ProcessTransmitter
Temperature
PE
4...20 mA or HART
loop powered
Non-intrinsically-safe installation / Ex e
Fuses for field terminals:
Very fast acting type (FF-Type)
before change.
Additional surge protection is
recommended in case of powerful or
recurrent strokes of lightning.
In case of blow out look for reason
Screen Screen Screen
Fuse 100mA
super fast
Fuse 100mA
super fast
Fuse 100mA
super fast
Fuse 1A
fast
-X