ACK Indication
Disable: There’s neither LED nor beeping indication for this setting.
Enable: There’s a specific LED and beeping indication for this setting.
3.5.4 Response Time-out, Baud Rate
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Serial Response Time-out
SS None 0
SS 200 mseconds 1
SS 500 mseconds 2
SS 800 mseconds 3
SS 1 second 4
SS 2 seconds 5
SS 3 seconds 6
SS 4 seconds 7
SS 5 seconds 8
SS 8 seconds 9
SS 10 seconds A
SS 15 seconds B
Baud Rate (BPS)
SS 38.4K BPS 0
SS 19.2K BPS 1
SS 9600 BPS 2
SS 4800 BPS 3
SS 2400 BPS 4
SS 1200 BPS 5
SS 57.6K BPS 8
SS 115.2K BPS 9
The Serial Response Time-out is a pre-defined delay time for the Hand-held scanner to wait for handshaking,
acknowledgment or non-acknowledgment from the host computer