3.9.5 Light Source On Time, Hands Free Time-out
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Light Source On Time
SS Short ( for IDM corded) 0
SS Medium 1
SS Long (for IDM Bluetooth) 2
SS Extremely long 3
Hands-free Time Out
SS Short 0
SS Medium 1
SS Long 2
SS Extremely long 3
SS Disable 4
Good Read Duration
SS Short 0
SS Medium 1
SS Long 2
SS Extremely long 3
SS Extremely short 4
Time Delay to Low Power
Standby Mode
SS 1 sec. 0
SS 3 sec. 1
SS 5 sec. 2
SS 7 sec. 3
SS 9 sec. 4
SS Immediate 5
Low Power Standby mode
Link Indication
SS Turn off immediately 0
SS Last for 1 minute 1
SS Keep on till power-off 2
Light Source On Time
This function is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level
Mode. The scanner keeps the light source on till the pre-defined light source on time is up.

Table of Contents

Other manuals for SICK IDM series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM series and is the answer not in the manual?

SICK IDM series Specifications

General IconGeneral
BrandSICK
ModelIDM series
CategoryBarcode Reader
LanguageEnglish

Related product manuals