NOTE
Setup is not supported for a Pharmacode.
1. Start Setup mode.
Press key 3 seconds 1
0%
100%
0%
100%
Ready
Result
|Test
|Teach
|Focus
|Setup
L/A GbE
Funct
Light
Ready
Result
|Test
|Teach
|Focus
|Setup
L/A GbE
Funct
Light
O
1 Press the p function button for 3 seconds.
2. Align the device with the code.
Figure 16: Test code
3. Select Setup.
Ready
Result
|Test
|Teach
|Focus
|Setup
L/A GbE
Funct
Light
O Ready |Test
Press key 2 x shortly 1
0%
100%
0%
100%
Result
|Teach
|Focus
|
L/A GbE
Funct
Light
O
Setup
1
Press button ▼ twice briefly.
✓
The Setup LED lights up blue.
4. Start Setup.
0%
100%
Result
|Teach
|Focus
L/A GbE
Funct
Light
O
Ready |Test
Ready |Test
Press key 1 x shortly 1
0%
100%
Result
|Teach
|Focus
L/A GbE
Funct
Light
|
Setup
|
Setup
Ö
1
Press the p function button once briefly.
✓
The Setup LED flashes blue.
The device adjusts itself automatically to suit the lighting conditions, working
distance, and quality of the code presented. According to the default setting, the
device permanently stores the values determined for the two parameter modules
(image, decoder) during this process, thereby overwriting the existing configura‐
tion.
COMMISSIONING 7
8018071/1E1C/2021-12-16 | SICK O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
53