01.202014/45 H39.ELEKS014EN-00
GENIUS 2.2 PANIC, Electromechanical mul-point lock
• Emergency opening in the direcon of escape: open
door using the lever handle or horizontal actuang
bar.
• Opening against the direcon of escape: unlock the
door using the key. Turn the key to the release stop.
The lever handle against the direcon of escape
is coupled once. Opening the door using the lever
handle.
• Locking in night mode: the door is automacally
locked. Aer using the escape funcon, access
against the direcon of escape is blocked again once
the door closes and it is not possible to escape back
into the building.
• Locking in day mode: there is no automac locking.
The lever handle against the direcon of escape is
always coupled. Acvate the lever handle to open
against the direcon of escape.
4
Opening in the direcon of escape is possible at any
me by acvaon of the lever handle or the horizontal
actuang bar.
Das Önen der Tür gegen die Fluchtrichtung ist erst
nach Entriegelung und Önen über den Schlüssel oder
der motorischen Önung über die GENIUS 2.2
PANIK Mehrfachverriegelung z. B. über ein Zutriskon-
trollsystem möglich. Aer using the escape funcon,
access against the direcon of escape is blocked again
once the door closes and it is not possible to escape
back into the building.
• Emergency opening in the direcon of escape: open
door using the lever handle or horizontal actuang
bar.
• Opening against the direcon of escape: unlock and
open the door using the key. Turn the key to the
release stop.
• Locking in night mode: the door is automacally
locked when it is closed.
• Locking in day mode: there is no automac locking.
Opening in the direcon of escape is possible at any
me by acvaon of the lever handle or the horizontal
actuang bar.
Opening the door against the direcon of escape via
the lever handle is only possible aer unlocking with
the key or by using the motorised unlocking via the
GENIUS 2.2 PANIC mul-point lock.