EasyManua.ls Logo

Siemens 1FK7 Series - Noise Emission

Siemens 1FK7 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
3.4 Design
Synchronous Motors 1FK7
Operating Instructions, 03/2011, 610.40700.40c
17
3.4.6 Noise emission
When operated in the speed range 0 to rated speed, 1FK7 motors can reach the following
measuring-surface sound pressure level Lp(A):
Table 3- 5 Sound pressure level
Shaft height Measuring-surface sound pressure level Lp(A)
1FK701 to 1FK704 55 dB(A) + 3 dB tolerance
1FK706 65 dB(A) + 3 dB tolerance
1FK708 to 1FK710 70 dB(A) + 3 dB tolerance
The motors are certified for a wide range of installation and operating conditions. These
conditions such as rigid or vibration-isolated foundation design influence noise emission,
sometimes significantly.
EUROSERVO SERVO MOTOR TAMİR MERKEZİ
WWW.EUROSERVO.COM.TR

Other manuals for Siemens 1FK7 Series

Related product manuals