Synchronous Motors 1FK7 
Operating Instructions, 03/2011, 610.40700.40c 
37 
Commissioning 
7
7.1  Measures prior to commissioning 
Before commissioning the system, check that it is properly installed and connected. The 
drive system must be commissioned as described in the operating instructions for the 
converter/inverter.  
 
DANGER 
 
Risk of electric shock 
When commissioning/operating electric motors, parts of the motor are always at a 
dangerous voltage. If this motor is not correctly handled/operated, this can result in death or 
severe personal injury as well as significant material damage. All of the warning information 
on the product must be carefully observed! 
 
WARNING 
 
Danger from rotating rotor. 
Provide the appropriate guards and covers for transmission elements. 
 
 
Note 
This list below does not claim to be complete. It may be necessary to perform additional 
checks and tests in accordance with the specific situation at the plant or system. 
 
 
Mechanical connection 
Make sure that: 
●  Touch protection measures are in place for moving and live parts. 
●  The fitted keys in the shaft extension (if available) must be firmly secured to prevent them 
from being flung out. 
●  The motor has been correctly installed and aligned. 
●  The rotor can turn without coming into contact with other parts and components. 
●  The operating conditions correspond to the data specified on the rating plate. 