Commissioning
7.1 Measures prior to commissioning
Synchronous Motors 1FK7
38 Operating Instructions, 03/2011, 610.40700.40c
All fixing screws, connecting elements, and electrical connections are tight and have
been attached properly.
The transmission elements have the proper setting conditions according to type, for
example:
Couplings are aligned and balanced.
The belt tension is properly adjusted if a belt drive is used.
Gear tooth flank play and gear tooth tip play as well as radial play are properly
adjusted if a gear drive is used.
Electrical connection
Make sure that:
The grounding and equipotential bonding connections have been established correctly.
The brake is operating perfectly.
The specified speed limit n
max
is not exceeded when operated from a converter.
Monitoring equipment
Make sure that:
Appropriately configured control and speed monitoring functions are being used to ensure
that the motor cannot exceed the permissible speeds specified on the rating plate.
Any supplementary motor monitoring devices and equipment have been correctly
connected and are fully functional.
Brake (optional)
Make sure that:
Applying the operating voltage causes the brake to open.
The brake functions (opens, closes) correctly.