Installation
5
5.1 Installation
CAUTION
Temperature-sensitive parts
Some parts of the electrical motor enclosure can reach temperatures that exceed 100 °C.
Temperature-sensitive components, e.g. cables, etc., can be damaged if they come into
direct contact with the motor enclosure.
When arranging temperature-sensitive components, ensure that they do not come into
contact with the motor enclosure.
CAUTION
Shaft extension
When installing and mounting the motor, ensure that the shaft extension is protected
against impact and pressure.
Note
Observe the technical data on the labeling plates on the motor enclosure.
The following must be taken into account when installing motors
Observe the data on the rating plate, as well as the warning and information plates on the
motor.
Observe permissible radial and axial forces (refer to the configuration manual). Axial
forces are not permitted for motors equipped with an integrated brake.
Check that the motors comply with the conditions (e.g. temperature, installation altitude)
at the installation location.
Their use is prohibited in hazardous zones and areas.
Ensure that the shaft extension is completely free of any anti-corrosion protection (use a
commercially available solvent).
For natural-cooled motors, it must be ensured that thermal losses can be properly
dissipated (see the chapter titled "Cooling").
If the motor is installed vertically with the shaft extension facing up, ensure that no liquid
can enter the upper bearing.
EUROSERVO SERVO MOTOR TAMİR MERKEZİ
WWW.EUROSERVO.COM.TR

Other manuals for Siemens 1FK7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1FK7 Series and is the answer not in the manual?

Siemens 1FK7 Series Specifications

General IconGeneral
Product typeSynchronous motor
EncoderIncremental encoder, absolute encoder
Cooling methodNatural cooling, forced-air cooling
Degree of protectionIP64, IP65
Speed rangeUp to 9000 rpm
Feedback systemEncoder or resolver