Connection   
6.2 Electrical connection 
  1FT7 synchronous motors 
34  Operating Instructions, 04/2010, 610.40075.40b 
6.2.4  Rotating the connectors 
Power connector, signal connector, and DRIVE-CLiQ can, to some extent, be rotated. A 
suitable socket connector can be used to rotate the angle plug. Make sure that the socket 
connector is completely secure to avoid damaging the pin contacts. 
 
NOTICE 
 
  It is not permissible to exceed the specified rotation range. 
  In order to guarantee the degree of protection, max. 10 revolutions are permissible. 
  Connectors should be rotated using the matching mating connector located on the 
connector thread. Only rotate the Sensor Module by hand. The use of pipe wrenches, 
hammers, or similar is not permitted. 
 
6
3
6
ar
6
3
3
6
)7[)7[)7[
)7[
)7[)7[
6L]H
6L]H
6L]H
)7[)7[
6L]H
 
Figure 6-4  Ability to rotate the connectors (P = power connector, S = signal connector) 
Table 6- 3  Maximum rotating torques that occur 
Connector  M
max
 
Power connector, size 1  12 Nm 
Power connector, size 1.5  20 Nm 
Signal connector  12 Nm 
DRIVE-CLiQ (connector)  8 Nm 
The size 3 power connector cannot be rotated. 
 
 
NOTICE 
 
Cable outlet direction 
If the direction of the cable outlet is not changed correctly, this can damage the connecting 
cables. The direction of the cable outlet must not be changed since this renders all warranty 
claims invalid.