A-7
TP27, TP37 Equipment Manual
Release 01/00
Control Panel Interface
Inputs
No. of inputs 16
Optical isolation from internal logic
circuitry
–
Input voltage
S rated value
S with signal “0”
S with signal “1”
24 V DC
0 to 5 V
15 to 30 V
Input current with signal “1” Typically 5 mA at 24 V
Input delay 0.3 msec
Connection of mechanical switches Possible
Bounce time v 10 msec
Cable length of sensors, unshielded 1 m
Technical Data