4 IQ-SENSE
13-13
Distributed I/O System ET 200S
EWA 4NEB 780 6024-02 07
Table 13-4 Enhanced Control Interface
Address Designation on
IQ-SENSE Opto FB
Assignment
Byte 2 Specify sensitivity/distance value on
channel 2
Bit 0:Bit 0:
1: Transfer sensitivity/distance value to the
WR_TEACH_VAL
sensor on channel 2
(using rising edge)
0: Deactivated
Bit 1 to bit 7:
Sensitivity/distance value
TEACH_VAL_IN
on channel 2: 1 to 126 (depending on the
sensor)
Teach-in on channel 2
Bit 0:
1: Start teach-in on the sensor on channel 2
(at the rising edge)
0: Deactivated
Bit 1 to bit 7: 0
START_TEACH
Byte 3 Specify sensitivity/distance value on
channel 3
Bit 0: WR_TEACH_VALBit 0:
1: Transfer sensitivity/distance value to the
WR_TEACH_VAL
sensor on channel 3
(using rising edge)
0: Deactivated
Bit 1 to bit 7:
Sensitivity/distance value
TEACH_VAL_IN
on channel 3: 1 to 126 (depending on the
sensor)
Teach-in on the sensor on channel 3
Bit 0:
1: Start teach-in on the sensor on channel 3
(at the rising edge)
0: Deactivated
Bit 1 to bit 7: 0
START_TEACH