Page #73 background imageLoading...
Page #73 background image
73 / 84
BA 9142 en 02/2015
10.6 Inspection
The inspection comprises all measures for ascertaining and assessing the actual condition.
The measures must be recorded.
Note
The record must be kept with these instructions.
Table 14: Inspection measures
Measures Periods Remarks
General visual check for cracks, leaks
and damage.
every 4 weeks
Visual check of the tooth-flank condition
for damage.
annually
Check oil filters of the oil-supply system
for contamination.
every 4 weeks
or if there is heavy
soiling
Optical display, see also operating
instructions oil-supply system.
Check of the instruments installed on
site (temperatures, oil pressures).
every 4 weeks
Inspection of the oil conducting lines for
leaks.
weekly
Oil level check at the oil level indicators
on the gear unit and, if necessary, on
the oil-supply system (version with
tank).
weekly See also operating instructions oil-supply
system.
Check for
- unusual noises,
- temperature,
- safety equipment.
weekly
Check of add-on parts such as
couplings, possibly auxiliary drive.
every 6 months See operating instructions for the
individual components.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Flender KMPP Series and is the answer not in the manual?

Siemens Flender KMPP Series Specifications

General IconGeneral
BrandSiemens
ModelFlender KMPP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals