10.7 Maintenance
Maintenance comprises all measures for preserving the required condition.
Table 15: Maintenance measures
Measures Periods Remarks
First oil change after start-up after approx. 1000 operating hours
or depending on the results of the
oil analysis carried out
See item 10.7.2
Oil analyses first one after 1000 operating
hours, all subsequent ones
annually
See item 10.7.1
Subsequent oil changes depending on the oil analysis
results; (without oil analysis: at the
latest after 18 months and/or
10000 operating hours)
See item 10.7.2
Clean the gear unit as required, at least every 2 years
See item 10.2.
Clean the air filter every 3 months
See it.em 10.3.
Replacing the air filter cartridge annually or when the air filter is
heavily soiled
See item 10.3.1.
Checking tightness of the foundation
bolts
every 12 weeks See item 10.7.3
General inspection of the gear unit every 2 years See item 10.11
Maintenance work on the oil-supply
system
See also operating instructions
oil-supply system.
See also operating instructions
oil-supply system.
Check couplings every 6 months See operating instructions
individual components.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Flender KMPP Series and is the answer not in the manual?

Siemens Flender KMPP Series Specifications

General IconGeneral
BrandSiemens
ModelFlender KMPP Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals