Expansion Module (EB)
Modules For internal distribution only
A31003-K1250-S100-12-7619
3-20 HiPath 1100, Service Manual
EB 204 Expansion Module
Interfaces
Figure 3-8 shows the distribution of extensions and external lines associated with the
EB 204 module connectors.
EB 204 Connector Assignments (CND)
Figure 3-8 EB 204 Module Overview - CND
Table 3-11 EB 204 Connector Assignments - CND
Contact X4 Connector X6 Connector X2 Connector X5 Connector
1 Connects to MB
through a power/
connection cable
Connects to the
MB through an
interconnect ca-
ble (flat cable)
a1 - extension 1 external line 1
2 b1 - extension 1 external line 2
3 a2 - extension 2
4 b2 - extension 2
5 a3 - extension 3
6 b3 - extension 3
7 a4 - extension 4
8 b4 - extension 4