ECO REFERENCE MANUAL
10-4
POWER AND MOTOR CONNECTIONS
- MICROMASTER Eco RANGE
PE
L/L1
N/L2
L3
PE
U
V
W
Motor
Terminals
DIP
Switch's
Control
Terminals
Input
Supply
Terminals
EMC
Earth
Gain Access to Terminals Frame Size A.
The power and motor terminals are directly
accessible beneath the inverter.
Gain Access to Terminals Frame Size B.
Power Connection Access
Insert the blade of a small screwdriver into slot A
in the front of the inverter and press in the
direction of the arrow. At the same time, press
down on tab B at the side of the access panel.
Removal of Terminal Cover
This will release the access panel, which will
then swing down on its rear-mounted hinges.
The access panel can be removed
from the inverter when at an angle of
approximately 30° to the horizontal.
If allowed to swing lower, the panel
will remain attached to the inverter.
D
E
C
F
G
H
Removal of Gland Plate
Remove the earthing screw C from the gland
plate.
Press both release catches D and E to release
the gland plate and then remove the metal gland
plate from the inverter.
B
A
F: Control cable input
G: Mains cable input
H: Motor cable output