1. Select the asset in the "Asset" tab.
2. Click on the asset icon, e. g. "MindConnect Nano".
3. Click next to "Status" on the button .
The following graphic shows the "Edit MindConnect" screen:
4. Activate DHCP if a DHCP server is available in your company network or enter the respective
information for static IP address.
The following graphic shows the IP address input fields:
5. Enter the proxy data area "Communication Settings" if necessary and click "Save".
In this case, contact your network administrator to get the proxy data. For Proxy IP
address input field, it is also possible to define the port number, for example:
127.0.0.1:8080.
For proxy authentication type NTLM: The domain and the username have to be provided
as "username@domain" or as "domain/username".
Overview of onboarding MindConnect Nano
2.5 Configuring network settings
MindConnect Nano
System Manual 7/2023 14