Environmental Conditions
NOTE
The device is only suitable for operation indoors.
Temperature
Recommended temperature during operation -25 °C to +70 °C
Temperature during transport -40 °C to +85 °C
Temperature during storage +10 °C to +85 °C
Humidity
Average relative humidity ≤ 75 %
Maximum relative humidity 93 % on 56 days per year
Condensation during operation Not permitted
Condensation during transport and storage Permitted
Other Environmental Information
Maximum altitude above sea level 2000 m
Degree of pollution 2
Protection class as per IEC 60529 IP 41
Overvoltage category III
5.3
Technical Data
5.3 Environmental Conditions
36 Accessories, RS232 Optical Fiber Converter 7XV5652-0CA00, Manual
C53000-G9050-C606-1, Edition 03.2020